Installation Overview
The first step to a great job is a great beginning, click here for the pre-installation checklist Pre-Install Checklist link
The next step to a great job is always the same no matter what the type of project click on the following link Basic Overall Project Walk Through
The MOST important part of the installation process is the refrigerant (freon) piping process. The House Call Company procedure when you have to connect or repair refrigerant piping or connections is:
-
Recover Refrigerant Recovery Process (Alternate to pump down into condenser) Pump Down
-
Connect/Repair Pipe/Fittings
-
Purge Nitrogen Purge
-
Braze Brazing
-
Pressure leak test Refrigerant Leak Testing Methods
-
Evacuation Evacuation
-
Evacuation and charging Evac&Charge Step by Step
-
Micron Leak Test Refrigerant Leak Testing Methods
-
Charge System
-
Confirm Operation in ALL modes and then demonstrate all modes to the client
Pre-Install Checklist link Basic Overall Project Walk Through